Venezuela, 21 de Octubre de 2014

Año 2011, Volumen 61 - Número 4
Año 2011, Volumen 61
Número 4


SLAN - Capítulo Venezolano

SLAN - México

SLAN - Brasil

SLAN - Chile






Desarrollado por:
Estudio Pro
Artículo No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Imprimir este Artículo Recomendar este Artículo Este Artículo no tiene versión en PDF Tamaño del Texto
HOME > EDICIONES > Año 2001, Volumen 51 - Número 1

Artículos Generales
Comparação da gordura corporal de mulheres idosas segundo antropometria, bioimpedância e DEXA

Aline Rodrigues Barbosa, José Maria Santarém, Wilson Jacob Filho, Eduardo Souza Meirelles, Maria de Fátima Nunes Marucci
Universidade da São Paulo, São Paulo. Brasil.

RESUMO
Comparação da gordura corporal de mulheres idosas segundo antropometria, bioimpedância e DEXA

Verificar a concordância e comparar o percentual de gordura corporal (%GC) através das medidas de dobras cutâneas (DC), bioimpedância (BIA) e DEXA. Foram avaliadas vinte mulheres voluntárias (62 a 79 anos), utilizando-se duas equações distintas para DC (19, 20) e BIA (23) e avaliação por DEXA. As estimativas do %GC foram comparadas através de análise de variância para medidas repetidas (ANOVA- Bonferroni), a correlação foi verificada pelo coef. de Pearson e a concordância pelo procedimento de Bland & Altman (25). O %GC obtido pela BIA apresentou baixa correlação (r<0,5) quando comparado com as duas equações de DC. Os valores do %GC variaram de 31,5 ± 5,5 a 41,2 ± 6,1 (média e desvio padrão) para Jackson (19) e DEXA, respectivamente. A análise de comparação múltipla mostrou que não foram observadas diferenças significativas (p>0,05) entre os métodos e/ou equações de BIA(RJL-CompCorp) vs. DC-Jackson (19). Para todas as outras comparações, as diferenças foram significativas (p <0,001). Na comparação entre RJL-CompCorp vs. Deurenberg (23), foi verificada boa concordância, assim como para DEXA vs. Durning e Womersley, (20). Embora os métodos e/ou equações utilizados nesse estudo sejam de ampla utilização para estimar a GC em indivíduos idosos, nenhuma técnica deve ser aceita como método único de referência nessa população Cada método apresenta limitações e a comparação pode ser útil para a interpretação dos resultados obtidos.

Palavras chave: Antropometria, DEXA, mulheres idosas, bioimpedância.

SUMMARY
Comparison of body fat using anthropometry, bioelectrical impedance and DEXA in elderly women

Verify correspondence and compare percentage body fat (%BF) estimates by skinfold thickness (SKT), bioelectrical impedance analysis (BIA) and DEXA. Twenty voluntaries women (aged 62 - 79 yr) were assessed. The body fat was estimated using two different equations of SKT(Jackson (19); Durning and Womersley, (20)), BIA using two-predictions formulas (23) and DEXA. To compare mean values of %BF was used analysis of variance for repeated measures (ANOVA _ Bonferroni), the correlation of the inter-method was verified by Pearson correlation coefficients (r), and correspondence between prediction formulas was tested by using the approach by Bland and Altman (25). The %BF assessed by BIA (23) shown poor correlation (r<0.5) with two SKT equations. The %BF ranged from 31.5 ± 5.5 to 41.2 ± 6.1 (mean ± SD) for Jackson (19) e DEXA, respectively. The analysis of variance shown no significant differences (p >0,05) between methods and/or equations by BIA (RJL-CompCorp) vs. DC-Jackson (19). There were observed significant differences (p < 0,001) between all comparisons. The correspondence between RJL-CompCorp vs. Deurenberg (23) was good and the same was observed for DEXA vs. Durning and Womersley (20). Although the methods and/or equations used in this study have been commonly utilized to estimate BF in elderly subjects, they neither must be used as a standard method. Each method has limitations and the comparison can be useful for interpretation of results.

Key words: Anthropometry, DEXA, bioelectrical impedance analysis (BIA), elderly women.





HOME > EDICIONES > Año 2001, Volumen 51 - Número 1 Ir al principio
Artículo No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14

PRIVACIDAD | ACCESIBILIDAD
ALAN-VE ISSN 0004-0622 - Depósito Legal: pp 199602DF83
Sociedad Latinoamericana de Nutrición
Producción editorial en Venezuela: Capítulo Venezolano - RIF: J-30843129-0
Urbanización Santa María, primera transversal, No. 417-214, Planta Alta
Tele-Fax: (+58-212) 283.8618
E-mail info@alanrevista.org
Código Postal: 1070
Caracas - Venezuela